Skip to content
  • There are no suggestions because the search field is empty.

FD20 Battery Recovery After Deep Discharge

Always refer to the manufacturer's Battery User Manual which can be found in this article in the Knowledge Base: Batteries: user manual and technical informations


If a lithium battery’s voltage drops below 21.6V it will be irreversibly damaged
. This state is typically called deep discharge.
If the batteries are left in the under-voltage state, it will at some point deplete itself to a point where it cannot be re charged again. Such a battery must be discarded.

To “wake” the BMS with the FarmDroid Battery Charger (part number C024PF025201) you should:

  1. Connect the battery to the charger
  2. Connect the charger to the 230v power supply

If the charger is plugged-in to the wall socket, when connecting to the battery, the pulse is not sent.

 

WARNING! ⚠️

Please note that the under-voltage protection is not to be viewed as a feature but instead as a safety measure and it is always the user’s responsibility to ensure that the voltage never drops below the under-voltage protection 
threshold (21.6V).

 

REACHING THE UNDER-VOLTAGE THRESHOLD WILL VOID ALL WARRANTIES GIVEN

 

If the pack is left in the under-voltage state, it will at some point deplete itself to a point where it cannot be recharged again. Such a battery must be discarded.